Tenderwize
Назад к поиску

Surgical sutures, hemostatics, and hand washing brushes

PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES·Skopje, MKD·MKD 1.7M·Deadline Jul 23, 2026 · 14 days left·Open·Supplies
Original notice title

North Macedonia – Medical equipments, pharmaceuticals and personal care products – Surgical sutures, other suture and hemostatic materials, and brushes for surgical hand washing

0/100

Opportunity Score

High riskLow complexity
SuppliesOpen
Why this score?

Opportunity

0 / 100

Complexity

0 / 100

Risk factors

Submission deadline in 14 days

Deep Portfolio Analysis

Deep Company Fit Analysis

Uses:

  • Description
  • Industries & Services
  • Capabilities
  • Market & Experience
  • Certifications

Buyer

Name

PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES

Location

Skopje, MKD

Identifier

7929420

Activity

Health

Lots (36)

LOT-0001

Non-absorbable multifilament silk suture coated with natural wax.

Non-absorbable multifilament silk suture coated with natural wax.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0002

Non-absorbable monofilament suture with needles having specific characteristics (tungsten-rhenium alloy) for CABG (Coronary Artery Bypass Grafting) procedures in cardiac surgery.

Non-absorbable monofilament suture with needles having specific characteristics (tungsten-rhenium alloy) for CABG (Coronary Artery Bypass Grafting) procedures in cardiac surgery.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0003

Absorbable synthetic multifilament suture made of Polyglactin 910, impregnated with triclosan, with tensile strength retention of 75% at 14 days, 50% at 21 days, and 25% at 28 days, and a complete absorption period of 56–70 days.

Absorbable synthetic multifilament suture made of Polyglactin 910, impregnated with triclosan, with tensile strength retention of 75% at 14 days, 50% at 21 days, and 25% at 28 days, and a complete absorption period of 56–70 days.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0004

Absorbable synthetic monofilament suture made of Polyglecaprone 25, impregnated with triclosan, with tensile strength retention of 60% at 7 days and 30% at 14 days, and an absorption period of 90–120 days.

Absorbable synthetic monofilament suture made of Polyglecaprone 25, impregnated with triclosan, with tensile strength retention of 60% at 7 days and 30% at 14 days, and an absorption period of 90–120 days.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0005

Absorbable synthetic monofilament suture made of Polydioxanone, impregnated with triclosan, with tensile strength retention of 60–80% at 14 days, 40–70% at 28 days, and 35–60% at 42 days, and an absorption period of 182–238 days.

Absorbable synthetic monofilament suture made of Polydioxanone, impregnated with triclosan, with tensile strength retention of 60–80% at 14 days, 40–70% at 28 days, and 35–60% at 42 days, and an absorption period of 182–238 days.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0006

Natural-origin hemostatic material made of oxidized regenerated cellulose (rayon) with a woven structure, carboxylic acid content of 19.5% w/w, pH value of less than 2.5, absorption time of 7–14 days, and bactericidal properties.

Natural-origin hemostatic material made of oxidized regenerated cellulose (rayon) with a woven structure, carboxylic acid content of 19.5% w/w, pH value of less than 2.5, absorption time of 7–14 days, and bactericidal properties.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0007

Non-absorbable coated polyester (polyethylene terephthalate) multifilament suture composed of high molecular weight, long-chain fibers with integrated aromatic rings of linear polyester, coated and impregnated with silicone.

Non-absorbable coated polyester (polyethylene terephthalate) multifilament suture composed of high molecular weight, long-chain fibers with integrated aromatic rings of linear polyester, coated and impregnated with silicone.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0008

Non-absorbable monofilament PTFE (polytetrafluoroethylene) undyed suture for chordae tendineae repair.

Non-absorbable monofilament PTFE (polytetrafluoroethylene) undyed suture for chordae tendineae repair.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0009

Rectangular PTFE pledgets.

Rectangular PTFE pledgets.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0010

Bovine pericardial patch treated with glutaraldehyde to enhance durability and prevent shrinkage and aneurysm formation. The elastic tissue adapts to the surface of application. With anti-calcification treatment that binds residual aldehydes, thereby reducing cytotoxicity and antigenicity. Dimensions: 10 × 14 cm ± 10%; thickness: 0.2–0.5 mm.

Bovine pericardial patch treated with glutaraldehyde to enhance durability and prevent shrinkage and aneurysm formation. The elastic tissue adapts to the surface of application. With anti-calcification treatment that binds residual aldehydes, thereby reducing cytotoxicity and antigenicity. Dimensions: 10 × 14 cm ± 10%; thickness: 0.2–0.5 mm.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0011

Silicone vessel loops for organ and blood vessel retraction, made of uncoated silicone, dimensions 2 × 2.5 mm, length 45 cm, available in red, blue, and yellow colours.

Silicone vessel loops for organ and blood vessel retraction, made of uncoated silicone, dimensions 2 × 2.5 mm, length 45 cm, available in red, blue, and yellow colours.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0012

Bone wax with a chemical composition of 70% beeswax and 30% petroleum jelly (vaseline), supplied as a 2.5 g bar.

Bone wax with a chemical composition of 70% beeswax and 30% petroleum jelly (vaseline), supplied as a 2.5 g bar.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0013

Titanium clips for blood vessel ligation – size S (small), 3.6 mm. The cartridge shall be adhesive and contain 9 clips. The clip shall have a pyramidal configuration with a triangular titanium profile to allow precise positioning.

Titanium clips for blood vessel ligation – size S (small), 3.6 mm. The cartridge shall be adhesive and contain 9 clips. The clip shall have a pyramidal configuration with a triangular titanium profile to allow precise positioning.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0014

Titanium clips for blood vessel ligation – size M (medium), 5.6 mm. The cartridge shall be adhesive and contain 9 clips. The clip shall have a pyramidal configuration with a triangular titanium profile to allow precise positioning.

Titanium clips for blood vessel ligation – size M (medium), 5.6 mm. The cartridge shall be adhesive and contain 9 clips. The clip shall have a pyramidal configuration with a triangular titanium profile to allow precise positioning.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0015

Neutral electrode with an effective contact area of 85 cm² (tolerance ±10%) and a ring area of 23 cm² (tolerance ±10%), compatible with the neutral electrode connection cable for the ERBE VIO® 3 electrosurgical generator or equivalent. Intended for use in all types of surgical procedures. The electrode shall be made of a flexible material capable of adapting to any body contour and shall be suitab

Neutral electrode with an effective contact area of 85 cm² (tolerance ±10%) and a ring area of 23 cm² (tolerance ±10%), compatible with the neutral electrode connection cable for the ERBE VIO® 3 electrosurgical generator or equivalent. Intended for use in all types of surgical procedures. The electrode shall be made of a flexible material capable of adapting to any body contour and shall be suitable for use in adult patients.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0016

Monofilament stainless steel suture wire (AISI 316L), uncoated, USP size 7, wire length 4 × 45 cm, with a 1/2-circle round-bodied sternum needle, needle length 48 mm.

Monofilament stainless steel suture wire (AISI 316L), uncoated, USP size 7, wire length 4 × 45 cm, with a 1/2-circle round-bodied sternum needle, needle length 48 mm.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0017

Epimyocardial unipolar electrodes for adults for temporary atrial and ventricular pacing, made of stainless steel, with twisted multifilament wire insulated with polyethylene, colour-coded, wire size 2/0, wire length 60 cm, and two needles: one 1/2-circle taper-point needle, 26 mm in length, and one straight reverse-cutting break-off needle, 65 mm in length.

Epimyocardial unipolar electrodes for adults for temporary atrial and ventricular pacing, made of stainless steel, with twisted multifilament wire insulated with polyethylene, colour-coded, wire size 2/0, wire length 60 cm, and two needles: one 1/2-circle taper-point needle, 26 mm in length, and one straight reverse-cutting break-off needle, 65 mm in length.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0018

Microsurgical knife with a rounded tip and a single sharp cutting edge, manufactured using grindless technology (without mechanical sharpening) to provide high precision and consistent blade geometry.

Microsurgical knife with a rounded tip and a single sharp cutting edge, manufactured using grindless technology (without mechanical sharpening) to provide high precision and consistent blade geometry.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0019

Sterile single-use wound retractor with a circular ring that provides 360° circumferential retraction and maximum exposure of the surgical field through a minimal incision. The device shall provide effective wound protection by creating a physical barrier that reduces the risk of surgical site infections, prevents bacterial contamination, and helps maintain an optimal moisture environment to promo

Sterile single-use wound retractor with a circular ring that provides 360° circumferential retraction and maximum exposure of the surgical field through a minimal incision. The device shall provide effective wound protection by creating a physical barrier that reduces the risk of surgical site infections, prevents bacterial contamination, and helps maintain an optimal moisture environment to promote wound healing. The retraction shall be atraumatic, evenly distributed, and free from localized pressure, thereby minimizing additional tissue trauma and patient discomfort. The device shall enable surgical procedures without the need for an assistant to hold a manual retractor. The retraction shall provide a tamponade effect and assist in minimizing bleeding. Available sizes shall include: Small (sheath length 18 cm, incision range 2.5–6 cm) and Medium (sheath length 18 cm, incision range 5–9 cm).

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0020

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 4 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.2 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 4 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.2 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0021

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 6 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.3 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 6 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.3 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0022

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 8 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.6 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 8 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.6 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0023

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 10 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.7 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 10 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.7 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0024

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 12 mm, a graduated catheter shaft, a catheter lumen with a diameter of 2 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 12 mm, a graduated catheter shaft, a catheter lumen with a diameter of 2 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0025

Automatic suture fastening system for valve surgery, consisting of at least two applicators with a minimum length of 16 cm and a diameter of 5–7 mm, and at least 12 fastening clips, suitable for open and minimally invasive surgical procedures..

Automatic suture fastening system for valve surgery, consisting of at least two applicators with a minimum length of 16 cm and a diameter of 5–7 mm, and at least 12 fastening clips, suitable for open and minimally invasive surgical procedures.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0026

Sterile non-woven PTFE (polytetrafluoroethylene) felt, dimensions 15.2 cm × 15.2 cm × 1.65 mm.

Sterile non-woven PTFE (polytetrafluoroethylene) felt, dimensions 15.2 cm × 15.2 cm × 1.65 mm.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0027

Sterile non-woven PTFE (polytetrafluoroethylene) felt, dimensions 2.5 cm × 15 cm × 1.65 mm.

Sterile non-woven PTFE (polytetrafluoroethylene) felt, dimensions 2.5 cm × 15 cm × 1.65 mm.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0028

Filter for a reusable sterilization container, made of PTFE (polytetrafluoroethylene), validated for at least 1,000 cleaning and sterilization cycles, suitable for fractional vacuum and gravity displacement sterilization processes, in accordance with EN 868-2 and DIN EN 554. The filter shall have an outer diameter of Ø190 mm and shall be compatible with the JK100 filter holders on the lids of the

Filter for a reusable sterilization container, made of PTFE (polytetrafluoroethylene), validated for at least 1,000 cleaning and sterilization cycles, suitable for fractional vacuum and gravity displacement sterilization processes, in accordance with EN 868-2 and DIN EN 554. The filter shall have an outer diameter of Ø190 mm and shall be compatible with the JK100 filter holders on the lids of the existing aluminium sterilization containers used at the Clinic.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0029

Heart stabilizer for off-pump (beating heart) cardiac surgery; low-profile design with vacuum system; two flexible stabilizers with 4 suction points each, each of which is fully bendable in all directions and adaptable to the anatomical structure of the heart and blood vessels. Suction regulation with vacuum regulator. Compatible with all retractors, with easy application and removal.

Heart stabilizer for off-pump (beating heart) cardiac surgery; low-profile design with vacuum system; two flexible stabilizers with 4 suction points each, each of which is fully bendable in all directions and adaptable to the anatomical structure of the heart and blood vessels. Suction regulation with vacuum regulator. Compatible with all retractors, with easy application and removal.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0030

Heart positioner based on a vacuum principle, for effective positioning of the apex of the heart or left ventricle using a silicone cup; compatible with all retractors; features a 360-degree rotating head; flexible system that allows normal movement of the heart during surgery.

Heart positioner based on a vacuum principle, for effective positioning of the apex of the heart or left ventricle using a silicone cup; compatible with all retractors; features a 360-degree rotating head; flexible system that allows normal movement of the heart during surgery.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0031

Aid for improved visualization of the surgical field, facilitates removal of blood through irrigation with a fine mist of saline solution, prevents drying and dehydration of sensitive tissue (10/box).

Aid for improved visualization of the surgical field, facilitates removal of blood through irrigation with a fine mist of saline solution, prevents drying and dehydration of sensitive tissue (10/box).

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0032

Non-absorbable polyfilament suture made of natural silk, wax-coated. Sterility, shelf life minimum 5 years. Thread thickness 1.

Non-absorbable polyfilament suture made of natural silk, wax-coated. Sterility, shelf life minimum 5 years. Thread thickness 1.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0033

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 2/0.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 2/0.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0034

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 0.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 0.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0035

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 3/0.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 3/0.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

LOT-0036

Sterile surgical brushes for washing hands for single use, made of sponge material impregnated with disinfectant containing chlorhexidine (minimum 4%), which directly acts on Gram-positive and Gram-negative bacteria.

Sterile surgical brushes for washing hands for single use, made of sponge material impregnated with disinfectant containing chlorhexidine (minimum 4%), which directly acts on Gram-positive and Gram-negative bacteria.

SuppliesEU fundedElectronic submission

Location

MK008, MKD

Duration

1 YEAR

Category

Medical equipments

Procurement Details

Publication date
24 cze 2026
Notice type
Contract notice — standard
Languages
English, Mkd

Reference metadata

Notice subtype
16
Notice version
1
Legal basis
32014L0024

Reference IDs

Tender ID
435106-2026

Documents (1)

Similar tenders