Tenderwize
Retour à la recherche

Matériel consommable pour interventions endovasculaires périphériques

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid·Ohrid, MKD·EUR 390.2k·Deadline Dec 09, 2026 · 21 days left·Open·Supplies
Titre original de l'avis

North Macedonia – Angiography supplies – Procurement of goods – dispensable material for endovascular procedures on the peripheral vascular system

0/100

Score d'opportunité

High riskLow complexity
SuppliesOpen
Pourquoi ce score ?

Opportunité

0 / 100

Complexité

0 / 100

Analyse approfondie du portefeuille

Analyse approfondie de l'adéquation entreprise

Utilise:

  • Description
  • Industries & Services
  • Capabilities
  • Market & Experience
  • Certifications

Informations clés

Pouvoir adjudicateur
Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid
Pays
Macédoine du Nord
CPV
33111710 - Angiography supplies
Date limite
Dec 09, 2026
Valeur estimée
EUR 390.2k

Analyse IA de l'appel d'offres

Tenderwize prépare une analyse IA de cet appel d'offres à partir de l'avis TED et des documents de consultation : périmètre, exigences clés, critères de sélection, risques et questions à poser à l'acheteur. L'analyse est générée à l'ouverture de l'appel d'offres.

Critères d'attribution

Lot 1

Price criterion

Lot 2

Price criterion

Lot 3

Price criterion

Lot 4

Price criterion

Lot 5

Price criterion

Lot 6

Price criterion

Lot 7

Price criterion

Lot 8

Price criterion

Lot 9

Price criterion

Lot 10

Price criterion

Lot 11

Price criterion

Lot 12

Price criterion

Lot 13

Price criterion

Lot 14

Price criterion

Lot 15

Price criterion

Lot 16

Price criterion

Lot 17

Price criterion

Lot 18

Price criterion

Lot 19

Price criterion

Lot 20

Price criterion

Lot 21

Price criterion

Lot 22

Price criterion

Lot 23

Price criterion

Lot 24

Price criterion

Lot 25

Price criterion

Lot 26

Price criterion

Lot 27

Price criterion

Lot 28

Price criterion

Lot 29

Price criterion

Lot 30

Price criterion

Lot 31

Price criterion

Lot 32

Price criterion

Lot 33

Price criterion

Lot 34

Price criterion

Lot 35

Price criterion

Lot 36

Price criterion

Lot 37

Price criterion

Lot 38

Price criterion

Lot 39

Price criterion

Lot 40

Price criterion

Lot 41

Price criterion

Lot 42

Price criterion

Lot 43

Price criterion

Lot 44

Price criterion

Lot 45

Price criterion

Lot 46

Price criterion

Lot 47

Price criterion

Lot 48

Price criterion

Acheteur

Lots (48)

LOT-0001

A peripheral self-expanding nitinol stent coated with a drug from the family Taxani directly on the stent, or an equivalent

-Z-Cell design with radiopaque markers on both ends of the stent - an ergonomic handle for positioning (single-hand stent deployment) - an internal port for rinsing - compatible with 0.035” wire and 6F introducer - stent length: 40-120mm - diameter: 5-8mm - catheter length: 80cm or 125cm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0002

A self-expanding vascular stent system with controlled drug release through a polymer, intended for treating peripheral vascular diseases

- the system shall be placed on a triaxial catheter for precise placement, with a working length of 130 cm - compatible with 0.035” (0.89 mm) guide wire and introducers with a maximum of 6F for all dimensions - stent diameters of 6mm and 7 mm - stent length: from 40 - 120 mm - the drug dose should not be more than 0.200 µg/mm² - the drug shall be released from the device surface in order to have a local effect on the tissue, and to reach a therapeutic concentration in a period of at least 12 months

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0003

A self-expanding carotid NITINOL stent with a flexible double layer MicroNet closed cell design for embolic protection

- Rx system - compatible with 5F introducer sheath - diameter: 5-10mm - stent length: 16-40 mm - a possibility for reposition during expansion of up to 50%

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0004

A self-expanding cobalt-chromium carotid stent, compatible with 0.014” guide wire and 5F introducer sheath

- the stent diameter shall adapt to the tapered shape of the carotid artery - there shall be a possibility of repositioning the wire up to 50% of the initial placement, allowing precise stent placement - to have a closed design that provides an increased protection for covering the lesion, plaque control, angiographic results and embolic protection during device removal - available in diameters from 5 mm to 9 mm, length from 30 mm to 50 mm - catheter length: 135 cm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0005

A self-expanding peripheral stent, 6 closed end interwoven nitinol wires, compatible with 0.014” and 0.018’’ guide wire, for treating symptomatic de novo or restenotic lesions on AFC or popliteal artery

- OTW technique - biomimetric - diameter: 4.5-6.5 mm - stent length: 20-200 mm - 6F compatible - catheter length: 120 cm maximum

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0006

A self-expanding peripheral nitinol stent with a flexible double layer MicroNet closed cell design, and a possibility for reposition during expansion of up to 50%

- compatible with 6F introducer sheath and 0.018” wire - Rx system - diameter: 5-8mm - stent length from 40 to 155 mm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0007

CoCr balloon-expandable stent with an open-cell design incorporating embedded peaks and helical connectors, OTW, low-profile, compatible with a 6F introducer and a 0.035” wire

- system length: 80 and 140 cm - 2 radiopaque markers - flexible with high radial strength - strut thickness: 125–150 μm - dimensions: diameter 5–10 mm, length 18–58 mm - tip profile: 0.036''

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0008

A self-expanding nitinol stent system intended for the treatment of iliac artery stenosis, compatible with a 0.035” guide wire and a 6F introducer

- manufactured using nitinol technology with a hybrid design, featuring an open-cell geometry in the central section for flexibility and a closed-cell design at the ends for precise placement - the distal and proximal sections should incorporate radiopaque markers for improved visualization - available in diameters from 6 to 12 mm and lengths from 20 to 120 mm - the system should have lengths of 75 cm and 120 cm and an ergonomic handle allowing gradual or rapid deployment

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0009

A self-expanding nitinol stent, flexible, with an open-cell design and 4 tantalum radiopaque markers at each end.

- delivery system featuring a three-layer catheter with 2 radiopaque markers - working length: 80 cm and 130 cm - compatible with a 6F introducer sheath and a 0.035” wire - dimensions: diameter 5–10 mm length 40–200 mm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0010

A self-expanding carotid stent system from a nitinol alloy, or an equivalent

- Straight and tapered configuration - with a so-called closed cell design - RX technique - diameter 6-10mm and length 20-40mm - compatible with 6F guiding introducer

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0011

A balloon-expandable stent for iliac blood vessels, or an equivalent

- stainless steel - with a so-called open cell design - radiopaque markers on both ends of the stent and balloon catheter - the stent shall be placed on a balloon catheter with a length of 80-135cm - the stent shall be based on the OTW system, compatible with a guide wire 0.035” - stent diameter: 5-10mm - compatible with 6-7F introducers - stent length: from 12mm or less, to 57 mm or more

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0012

A peripheral stent onto a balloon, made of Co-Cro, compatible with 6F introducer

- OTW system - struts thickness: 110μm (5-7mm) - with PROBIO coating (amоrphous silicon carbidе) - compatible with a 0.035" guide wire - on a carrier available in lengths of 90,135 and 170cm - stent length: 18 - 78mm - diameter: 5-10mm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0013

A self-expanding nitinol stent equipped with a single-hand ergonomic system for placement, or an equivalent

- with a so-called open cell design - equipped with a single-hand ergonomic system for placement with a triaxial design with a mechanism for accurate stent positioning -OTW technique - compatible with 5F introducer and 0.035" guide wire - catheter length: 80cm-150cm - stent diameter: 5-8mm - stent length: 20-150mm and longer

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0014

A balloon catheter for percutaneous transluminal angioplasty (PTA) of lesions in the peripheral arteries such as the internal pudendal, iliac, renal, popliteal, femoral, iliofemoral, anterior and posterior tibial, peroneal, pedal, radial, brachial, and ulnar

- OTW technique - catheter length: 50cm-150cm+/-5% - balloon length from 2cm to 12cm, or longer - inflatable balloon with a diameter from 1.5mm to 3mm, or larger - burst pressure:16atm+/-5% - accepts 0.014“ guide wire - compatible with a “sheath“ of 3F

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0015

A system for distal embolization prevention comprised of: a catheter containing a wire with nitinol filter mesh with three different porosities (proximal, central, and distal), as well as radiopaque markers on the distal and proximal ends, and on the entire proximal opening of the filter

- shall be indicated for carotid, coronary, and peripheral interventional procedures - the system shall allow independent movement of the wire and enable longitudinal and rotational movement of the filter - to include an option to fracture the wire and use the remaining portion as the primary guide wire through the catheter based on the RX technique - filter dimension: 3-7mm - wire length: 320/190cm (+/-5cm), compatible with a guide wire with a diameter of 0.014-0.018" and 5F introducer

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0016

Distal embolic protection during carotid stenting should maintain continuous blood flow while effectively preventing embolization of plaque fragments that could lead to adverse complications, such as strokes

- compatible with 6F catheter, length 190 cm and 300 cm - MR 0.014 system - profile: 3.2 F (1.1mm) - nitinol filter loop

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0017

A peripheral balloon catheter coated with the drug Paclitaxel for de novo or lesions with restenosis, 0.035'' compatible, with Paclitaxel remaining present in the tissue for up to 180 days

- over-the-wire (OTW) - 0.035'' compatible - diameter 4.00-12.00mm, in 1 mm increments - length: 40-60-80-120-150, 200, 250mm - compatible with 5-6-7-9F introducer - catheter length: 80 and 130cm (for all available balloon sizes)

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0018

Balloon catheters for peripheral arteries for high-pressure procedures

- ОТW technique - compatible with 0.035’’ wires - balloon diameter: 4.0-8.0mm - length: 20.0mm - 80.0 mm, or longer - compatible with 5-7F introducers - nominal pressure: 10bar+/-5%

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0019

BBalloon catheters for peripheral arteries

- ОТW technique - hydrophilic coating - “dual lumen shaft“ - compatible with 0.035’’ wires - balloon diameter: 3.0-12.0mm - length: 20.0-300.0 mm - compatible with 5-7F introducers - catheter length: 80cm,130cm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0020

PTA balloon catheter with a diameter of a guide wire of 0.035" (0.89 mm), non-compliant, intended for high-pressure dilation with a working pressure of up to 24 atm

- a balloon catheter made of material that provides both trackability and high-pressure within the same balloon - compatible with 5F (1.67 mm) introducers for balloons up to 7 mm, и 6F (2.00 mm) for balloons up to 10 mm - available in balloon lengths from 20mm to 200 mm, diameters from 3 mm to 12 mm and catheter length of 75 cm and 135 cm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0021

Catheters for bipolar radiofrequency segmental ablation of the superficial veins of lower extremities, with manual activation

- ablation active zone length: 3cm, 7cm or 8cm - catheter working length: 60-100cm - with depth markers - with a 0.025“ guide wire lumen - 6 и 7F

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0022

A pedal introducer set for micropuncture

- with a nitinol guide wire with a platinum tip, with a diameter of 0.018 “and length 40cm+/-5% - introducer with: inner diameter of 2.9F, outer diameter from 4.0 to 5.0F, and length 7cm ±5% - echogenic needle 21G, length 4 cm (+/-5%) and echogenic tip - “Check-flow“ valve

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0023

A catheter for support used for small blood vessels or for superselective anatomy for diagnostic or interventional procedures, as well as for peripheral use

- catheter of 2.3-2.6F that can be inserted through 4F catheter with length from 65cm to 150cm - accepts guide wire with a diameter from 0.014“ to 0.018“ - platinum and iridium markers - with either a curved or straight tip

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0024

A single-lumen infusion catheter for thrombolysis with an occlusive valve on the distal end and side spray holes – pulse infusion of thrombolytics, with distal and proximal marker on the infusion length, and a possibility for an infusion without a guide wire

- length: 40-135cm - infusion length: 5-50cm - diameter: 4-5F - compatible with 0.035-0.038" guide wire

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0025

Peripheral catheters for support

- with a double inner mesh and 3 radiopaque markers positioned at 4 and 6cm from the tip for precise lesion measurement and stent or balloon positioning - diameter: 4F - compatible with 0.035” wire - length: 150cm (+/-5%) - with straight or 30º curved tip

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0026

A peripheral balloon for PTA coated with the drug Paclitaxel, a drug dose of minimum 3.0 μg/mm2, on a carrier from the citrate group or an equivalent

- OTW system (for OTW technique) - compatible with 0.018“ wire - balloon diameter: from 2-7 mm, or larger - balloon length: from 40-120 mm, or longer - guiding catheters length: 90-150cm - compatible with 4F and 5F

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0027

A peripheral PTA balloon catheter with Paclitaxel coating (2 μg/mm²) on a 0.018" platform, designed for optimal drug transfer and minimized distal particle loss. Suitable for treatment of high-risk lesions, such as calcified stenoses, diabetes and total occlusions

-- with lesion entry profile of 0.020" (0.51 mm) - deflation time: 10 seconds - available in diameters from 2 to 8 mm - lengths from 40 to 200 mm and - shaft lengths of 90, 135 и 150 cm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0028

A hydrophilic balloon dilation catheter, made of semi-crystalline polymer (SCP) or equivalent, OTW system, compatible with 0.035″ guide wire

- catheter length of 90, 130 и 170 cm - balloon diameter: 3 -12 mm - with various balloon lengths from 20 to 250mm - with two markers - compatible with 5F, 6F and 7F introducer

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0029

A PTA balloon catheter for dilation, semi-compliant, available in Monorail™ (Rx) and Over-the-Wire (OTW) design, compatible with 0.018" (0.46 mm) guide wire

- made of Pebax semi-compliant balloon material with hydrophilic coating or equivalent - the tip is tapered, with a lesion entry profile not larger than 0.020” (0.51 mm) - deflation time: maximum 10 seconds - balloon diameter from 2.0 mm to 10.0 mm and length from 10 mm to 220 mm - the catheter shall be available with shaft lengths from 90 cm to 150 cm - compatible with 5F introducer - suitable for broad clinical applications, including carotid and post-stent interventions

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0030

A set for nontumescent nonthermal ablation of veins with medical cyanoacrylate adhesive

The set shall contain: - 5 cc vial with adhesive - 5F delivery catheter with a minimum length of 91cm - two laser markers for high echogenic visibility - 7F introducer with a minimum length of 80cm - 5F dilator with a minimum length of 87cm - applicator with an ergonomic pistol-shaped handle, allowing controlled release of 0.10cc adhesive during application - 0.035" guide wire with J-tip - two 3cc syringes

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0031

A tubing set for an infiltration pump for tumescent anesthesia

- tubing length: minimum 2m - the tubing shall be made of PVC with a silicone section for the infusion roller pump - one side of the tubing shall end with an integrated luer lock- connector and spike-connector with port on the other side -the set shall include an adjustable safety clamp to open/close fluid flow - an integrated connector for easy attachment of the tubing to the fluid bottle - an integrated valve for fluid release

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0032

A hydrophilic balloon catheter for peripheral arteries, non-compliant, OTW design, compatible with 0.014″ guide wire

- catheter length: 90,150,200 cm - balloon diameter: 1.5 mm to 6.0 mm - balloon length: 20-240 mm - compatible with 4-6F introducer - with 2 radiopaque markers (20-150mm) and 4 (180-240mm) - NP 12atm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0033

A hydrophilic balloon catheter for peripheral arteries, non-compliant, OTW design, compatible with 0.035″ guide wire

- catheter length: 75,135,200 cm - balloon diameter: 3 to 7.0 mm - balloon length: 20-240 mm - compatible with 5-7F introducer - with 2 radiopaque markers (20-150mm) and 4 (180-240mm) - NP 12atm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0034

A hydrophilic and flexible introducer for peripheral interventions, with a support coil to prevent kinking and a radiopaque tip marker, also suitable for carotid procedures

- with length up to 110 cm, straight tip - with an outer diameter of 6F - with an inner diameter of at least 2.21mm - PTFE inner lining - with Tuohy-Borst Sidearm valve and dilator with length of 122/102cm - compatible with 0.038” wire

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0035

A hydrophilic guiding (sheath) introducer for peripheral interventions, featuring a steel coil for kink resistance and a radiopaque marker at the tip, with an inner PTFE layer and an outer nylon layer coated with a hydrophilic coating

- length range: 45–90 cm - outer diameter: 5F–8F - with either a straight or curved tip - hydrophilic coating from 5 to 35 cm on the distal end - with a Tuohy-Borst Sidearm and a Cross-cut valve - compatible with a 0.038” wire

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0036

Distal embolic protection for carotid stenting with independent 0.014″ guide wire placement technology, three levels of wire support, and sequential deployment of the embolic protection filter

- embolic protection filter with dimensions of 5 and 7.2mm and pores of at least 120 microns - the system includes a collection catheter - the entire system is compatible with 5F introducer or 6F guiding catheter

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0037

A balloon catheter for peripheral arterial and carotid dilation, for RX (rapid exchange), compatible with 0.014″ wire, with rapid inflation and deflation capability, and quick removal from the dilation site

- RX (rapid exchange) - diameter range from 4.0 to 7.0mm - length from 15 to 40mm - shaft length: 80-135cm - compatible with 6F guiding catheter - RBP 14atm for all sizes

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0038

A catheter system compatible with 0.014″ guide wire, intended for mechanical treatment of vascular lesions in peripheral arterial disease, including long, calcified, thrombotic, and chronically occluded segments

- the system shall provide rotational, frontal, and expandable cutting with blades rotating at approximately 70,000 rotations per minute - to have a minimum of five frontal blades for initial lesion engagement and treatment of stenotic or occluded vessels - to use an “up/down” blade technology to allow flexibility for treating multiple vessel diameters with a single catheter - to include active and continuous mechanical aspiration to remove thrombus and debris, reducing the risk of distal embolization and ensuring optimal debulking - the cutting mechanism shall be differential, selectively removing the diseased, non-elastic tissue from the healthy vascular tissue that needs to remain protected - the catheter shall contain internal lumens for infusion, aspiration, and guide wire navigation, as well as external ports for solution and aspiration - the catheter length shall be 120 cm, 135 cm or 145 cm, depending on configuration - all variants shall be compatible with 7 F introducer and 0.014” guide wire

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0039

DEB peripheral balloon catheter for PTA, OTW technique, coated with Paclitaxel on a Butyryl-tri-hexyl citrate (BTHC) carrier, maximum guide wire 0.018″

- two embedded Platinum-iridium markers - compatible with 5-6F introducer - balloon diameter: 2-7mm - balloon length: 40,60,80,120,150mm - catheter length: 85 and 150cm for all available balloon sizes - max guide wire 0.018'' - inflation time of at least 30 secunds - Paclitaxel drug dose: 3.0 μg/mm2

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0040

A peripheral balloon catheter for PTA coated with Sirolimus on a lipid-based carrier in the form of micro-reservoirs, drug dose 1 μg/mm2

- OTW system - compatible with 0.018'' wire - balloon diameter from 2-7mm - balloon length: 40-150mm - length of the guiding catheters: 135cm - compatible with 5F-7F introducers

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0041

A guide wire for peripheral interventions in chronic occlusions, for peripheral interventions using penetrating techniques, featuring a tapered tip and diameter of 0.014” and 0.018”

- minimum 15 cm of radiopacity at the tip - tapered tip from 0.008 to 0.013” - tip load: 20, 30, and 40 g - single-core design - length: 180–300 cm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0042

A set for foreign body retrieval from the cardiovascular system, with a torque device

- the set should consist of three snares made of nitinol and platinum, and a catheter with a radiopaque marker - the snare should have a diameter from 6 to 45 mm and overall length of 120 and 175 cm - the catheter should be 3.2, 6, and 7F, with length of 100 and 150 cm - the set should include a torque device

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0043

A micropuncture introducer set with no transition between the introducer and dilator, featuring a 4F outer diameter introducer, a 0.018” nitinol guide wire, and a palladium tip

- introducer length: 10 cm - introducer outer diameter: 4F - nitinol guide wire (0.018”) length: 40 cm - 21G needle with an echogenic tip and a length of 7 cm - palladium tip

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0044

A low-pressure balloon catheter for femoral and iliac blood vessels, compatible with a ShockWave Medical generator or equivalent

- five emitters - diameter from 3.5 to 8.0 mm - length: 60 mm - 30 pulses in 10 cycles - catheter working length: 135 cm - compatible with a 6F introducer for diameters from 3.5 to 7.0 mm, and - compatible with a 7F introducer for an 8.0 mm diameter - the catheters should be supplied with a protective sleeve to cover the cable connection between the generator and the catheter

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0045

A sterile, single-use guide sheath introducer intended for the introduction of diagnostic and interventional devices into the peripheral and coronary vasculature. It should feature a metal spiral reinforcement (coiled wire technology) for high kink resistance and compression during navigation through tortuous blood vessels, compatible with 0.018” and/or 0.035”/0.038” guide wires

- the distal section should have a hydrophilic coating to facilitate insertion and improve navigation through blood vessels - to be radiopaque along its entire length and feature a radiopaque marker positioned approximately 5 mm from the distal tip for precise fluoroscopic visualization - to incorporate an integrated hemostatic valve to minimize blood loss during the procedure - lengths: at least 45 cm, 65 cm, and 90 cm - sizes: at least 4F to 8F - with various tip configurations: Straight, Multipurpose, Hockey Stick, and Renal Double Curve - compatible with 0.018” and/or 0.035”/0.038” guide wires, depending on sheath size The set should include a guide sheath introducer, dilator, and adapter with a hemostatic valve. It should be non-pyrogenic, latex-free, and individually sterile packaged.

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0046

A semi-compliant PTA balloon coated with a Paclitaxel drug coating 3 μg/mm², with a lipophilic organic ester in an 80/20 ratio, multilayer coating with prolonged drug availability for long-term efficacy

- catheter lengths: 80, 100, 140, and 150 cm - 2 tungsten radiopaque markers - compatible with 4, 5, and 6F introducer and 0.014”-0.035” wires - nominal pressure: 6–7 atm - RBP: 14–16 atm - dimensions: diameter 1.5–8 mm and length 20–200 mm

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0047

OTW balloon catheter made of nylon/PEBAX material, semi-compliant, with a 0.036” tip profile and a tapered, atraumatic design for the most challenging lesions, crossing profile: 0.057”–0.083”

-- catheter length: 80, 140, and 200 cm - coated with a silicone layer - 2 radiopaque markers - tip profile: 0.036” - crossing profile: 0.057”–0.083”

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

LOT-0048

A peripheral balloon catheter coated with a Paclitaxel drug 3.5 μg/mm², for de novo or restenotic lesions, with Paclitaxel remaining present in the tissue for up to 180 days

-OTW technique - 0.018” compatible - minimum diameter range: 4.00–7.00 mm, in 1 mm increments - length: 40, 60, 80, 120, and 150 mm - compatible with 5F introducer - catheter length: 80 and 130 cm for all available balloon sizes

SuppliesEU fundedElectronic submission

EUR 390.2k

Valeur estimée

Localisation

MKD

Catégorie

Angiography supplies

Critères d'attribution

Price

Détails de la procédure

Date de publication
15 Nov 2026
Langues
English, Mkd

Métadonnées de référence

Base juridique
32014L0024

Identifiants de référence

ID de l'appel d'offres
796326-2026

Documents (1)

Appels d'offres similaires

Cookies & Privacy

With your consent, we use Google Analytics, Microsoft Clarity (session recordings) and Google Ads cookies to understand how Tenderwize is used and to measure our advertising. You can change your choice at any time via “Cookie Settings” in the footer. Cookie Policy · Privacy Policy