Regulated Transformers 40/50 MVA, 110/16 kV ONAN/ONAF

Elektrizitätswerke des Kantons Zürich·Zürich, Switzerland·Expired · Aug 21, 2026·Open·Supplies
Structured notice only
Titre original de l'avis

Switzerland – Power supply transformers – Reguliertransformatoren 40/50 MVA, 110/16 kV ONAN/ONAF

40/100

Score d'opportunité

Needs reviewMedium complexity
SuppliesExpired
Pourquoi ce score ?

Opportunité

40 / 100

Complexité

45 / 100

Facteurs de risque

No estimated value, procurement documents, or eligibility criteria available; decisions cannot be properly evaluated.

Structured data indicates EU-funded, but XML notice states no EU funds. This may affect project conditions or reporting...

No procurement documents available

Analyse approfondie du portefeuille

Analyse approfondie de l'adéquation entreprise

Utilise:

  • Description
  • Industries & Services
  • Capabilities
  • Market & Experience
  • Certifications

Aperçu

Moderate opportunity

Faits clés

  • Supplies contract
  • 1 lot
  • Supply and installation of regulated power transformers 40/50 MVA, 110/16 kV ONAN/ONAF
  • Quantity of 6 to 11 units
Afficher le résumé complet

This is an open tender by Elektrizitätswerke des Kantons Zürich (EKZ) for the supply and installation of 6 to 11 regulated power transformers (40/50 MVA, 110/16 kV ONAN/ONAF). The procedure is governed by EU Directive 2014/25 (utilities). Key missing information includes estimated value, procurement documents, and explicit eligibility criteria. The notice is available in German only. The deadline is 2026-08-21 10:00 (structured data) with a discrepancy in the XML notice indicating 12:00. There is an inconsistency regarding EU funding: structured data indicates EU-funded, but XML notice states no EU funds.

Risques

No estimated value, procurement documents, or eligibility criteria available; decisions cannot be properly evaluated.

Structured data indicates EU-funded, but XML notice states no EU funds. This may affect project conditions or reporting...

No procurement documents available

L'analyse peut être incomplète

Seule une partie des documents de consultation a été analysée. Des exigences, certificats ou documents de soumission supplémentaires peuvent exister dans les documents restants.

Exigences clés

Technical

  • Transformers must meet specified technical parameters (40/50 MVA, 110/16 kV, ONAN/ONAF)
  • Delivery and installation at Dietikon, Switzerland

Administrative

  • Compliance with contractual conditions in document 5

Les exigences peuvent être incomplètes.

Critères d'attribution

Lot 1

Price criterion with 40% weight, including loss capitalization40%Quality criterion with 50% weight50%References criterion with 10% weight10%

Acheteur

Localisation

Zürich, CHE

Site web

www.ekz.ch

Identifiant

8b31febb-62cd-47fe-9cd8-3e657a4691db

Activité

Electricity-related activities

Lots (1)

LOT-0000

Regulated Transformers 40/50 MVA, 110/16 kV ONAN/ONAF

Supply and installation of 6 to 11 regulated power transformers. Detailed requirements in the specification (document 2) and contract template (document 5).

SuppliesEU fundedElectronic submission

Localisation

Dietikon, Switzerland

Catégorie

Power supply transformers

Critères d'attribution

Best price-quality ratio

Date limite

Expired Aug 21, 2026

Détails de la procédure

Date de publication
21 Jun 2026
Langues
German

Métadonnées de référence

Base juridique
32014L0025

Identifiants de référence

ID de l'appel d'offres
425445-2026

Documents (1)